Contents
Images
Upload your image
DSS Images Other Images
Related articles
Improvement of Hipparcos Proper Motions in Declination More than a decade elapsed after the HIPPARCOS ESA mission (ESA 1997)observations have been collected. This first astronomical satellitemission was less than 4 years long so that 1991.25 is the epoch of theHIPPARCOS Catalogue. Many other projects have checked or improvedHIPPARCOS data. Also, a long series of ground - based opticalobservations of some stars included in HIPPARCOS Catalogue, made withPhotographic Zenith Tubes (PZT) are useful for the task of improving theproper motions of these stars. The ARIHIP Catalogue (after ACT, TYCHO -2, FK6, GC+HIP, TYC2+HIP) is a combination of the HIPPARCOS and someground - based data, and the ARIHIP proper motions are more accuratethan the HIPPARCOS ones. Here we present a new step of our procedure ofcalculation; between PZT data we added the HIPPARCOS position withsuitable weight - the point with the coordinates (1991.25, 0ŭ0)in our case. The method was applied to 202 stars observed at RichmondPZTs in the course of a few decades. The result is better proper motionsin declination for these HIPPARCOS stars, and a good agreement withARIHIP proper motions (we found 128 common Richmond and ARIHIP stars tocheck our result). Also, we present the result for other 74 Richmondstars which are not found in ARIHIP.
| Towards a fundamental calibration of stellar parameters of A, F, G, K dwarfs and giants I report on the implementation of the empirical surface brightnesstechnique using the near-infrared Johnson broadband { (V-K)} colour assuitable sampling observable aimed at providing accurate effectivetemperatures of 537 dwarfs and giants of A-F-G-K spectral-type selectedfor a flux calibration of the Infrared Space Observatory (ISO). Thesurface brightness-colour correlation is carefully calibrated using aset of high-precision angular diameters measured by moderninterferometry techniques. The stellar sizes predicted by thiscorrelation are then combined with the bolometric flux measurementsavailable for a subset of 327 ISO standard stars in order to determineone-dimensional { (T, V-K)} temperature scales of dwarfs and giants. Theresulting very tight relationships show an intrinsic scatter induced byobservational photometry and bolometric flux measurements well below thetarget accuracy of +/- 1 % required for temperature determinations ofthe ISO standards. Major improvements related to the actual directcalibration are the high-precision broadband { K} magnitudes obtainedfor this purpose and the use of Hipparcos parallaxes for dereddeningphotometric data. The temperature scale of F-G-K dwarfs shows thesmallest random errors closely consistent with those affecting theobservational photometry alone, indicating a negligible contributionfrom the component due to the bolometric flux measurements despite thewide range in metallicity for these stars. A more detailed analysisusing a subset of selected dwarfs with large metallicity gradientsstrongly supports the actual bolometric fluxes as being practicallyunaffected by the metallicity of field stars, in contrast with recentresults claiming somewhat significant effects. The temperature scale ofF-G-K giants is affected by random errors much larger than those ofdwarfs, indicating that most of the relevant component of the scattercomes from the bolometric flux measurements. Since the giants have smallmetallicities, only gravity effects become likely responsible for theincreased level of scatter. The empirical stellar temperatures withsmall model-dependent corrections are compared with the semiempiricaldata by the Infrared Flux Method (IRFM) using the large sample of 327comparison stars. One major achievement is that all empirical andsemiempirical temperature estimates of F-G-K giants and dwarfs are foundto be closely consistent between each other to within +/- 1 %. However,there is also evidence for somewhat significant differential effects.These include an average systematic shift of (2.33 +/- 0.13) % affectingthe A-type stars, the semiempirical estimates being too low by thisamount, and an additional component of scatter as significant as +/- 1 %affecting all the comparison stars. The systematic effect confirms theresults from other investigations and indicates that previousdiscrepancies in applying the IRFM to A-type stars are not yet removedby using new LTE line-blanketed model atmospheres along with the updatedabsolute flux calibration, whereas the additional random component isfound to disappear in a broadband version of the IRFM using an infraredreference flux derived from wide rather than narrow band photometricdata. Table 1 and 2 are only available in the electronic form of thispaper
| Star catalogs for the Washington and Richmond photographic zenith tubes. Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1973AJ.....78..642M&db_key=AST
| UBV Photometry of 173 PZT Stars Abstract image available at:http://adsabs.harvard.edu/cgi-bin/nph-bib_query?1971PASP...83..177W&db_key=AST
|
Submit a new article
Related links
Submit a new link
Member of following groups:
|
Observation and Astrometry data
Constellation: | Αλώπηξ |
Right ascension: | 21h24m48.10s |
Declination: | +25°52'49.6" |
Apparent magnitude: | 7.053 |
Distance: | 189.753 parsecs |
Proper motion RA: | 15.7 |
Proper motion Dec: | -2.7 |
B-T magnitude: | 7.103 |
V-T magnitude: | 7.058 |
Catalogs and designations:
|